How to provide boiler thermal efficiency thermal efficiency of the coal heating steam boiler 3 ton per hour has the following methods: low-pressure boiler at the factory has been designed considering the problem of thermal efficiency of the boiler, the flue gas from the device or change little aspects of energy-saving possibilities, it is best to start from the energy-saving operation (here talk recovered water vapor condensation method). The current design thermal efficiency of domestic low-pressure boiler is generally 70 to 90%, generally the actual operation of the thermal efficiency of about 60 to 80%, some even below 50%, a small low pressure industry as long as the operation, maintenance properly, can meet the design thermal efficiency of manufacturers. I think the management and operation should pay attention to the following points: First, the boiler flue gas temperature monitoring. Typically the maximum exhaust heat loss is loss, it is important to good control of exhaust gas temperature, exhaust gas temperature is generally low pressure coal-fired boiler of 150 ~ 180 ℃, fuel boiler exhaust gas temperature is 210 ~ 240 ℃, so when the boiler to find out why when the exhaust temperature is too high and promptly eliminated. Coal-fired boiler flue gas temperature is too high reasons are: high furnace pressure; shorting smoke; thick soot on the heat pipe; thick scale pot like. High temperature fuel exhaust reasons are: 1 air not adjusted oil, the oil is not completely burned in the chimney the secondary combustion occurs aft; 2 soot too, the need for timely cleaning; 3 shorting smoke; 4.... thick scale; Second, controlling blowdown rate. Without restricting the general rate of industrial sewage control in 5 to 10%, in the pot of water to ensure that qualified (mainly total alkalinity and pH value), the blowdown rate as low as possible, the sewage to adhere to the "ground row, row less, are ranked "the rules. Third, the maintenance of good furnace wall insulation. The heat loss is also a relatively large heat losses, now the manufacturers in the manufacturing and design has been well thought out, so we do not need to change, we just trying to be difficult to maintain. Outer surface temperature generally does not exceed 50 ℃, it will have to find out the reasons such as too high, and remove. Boiler insulation should always be kept dry, for coal, not a long positive run, or easy to damage the coal furnace wall and gate and so on. Fourth, adjust the ratio of fuel and air volume, complete combustion of the fuel as possible. Generally do not have a small amount of wind testing instruments, we can only go by experience adjustment. For oil, the normal combustion flame was yellow-white, non-glare, flame stability, no visible smoke chimney; For coal, the normal combustion flame pale, no visible smoke chimney, basic cinder burn coal particles as even as possible. Fifth, the need for a sound water treatment. Improve water treatment and water quality testing can maximize prevent fouling and correct guidance of the sewage, but it did not do a lot of small, companies usually do not pay attention.

The Fangkuai Group's unique full-operating boiler operation laboratory has an annual operating cost of more than 5 million yuan, which can simulate the operating conditions of various types of boilers under multi-operating environment conditions. The laboratory provides technical tests such as test and inspection, analysis and evaluation, data evaluation, energy saving and environmental protection, and special software from materials to complete equipment, hardware to software, and even complex large systems.

Learning materials heat boiler 1, the boiler is three safety accessories: water gauge, pressure gauge, safety valve. 2, the normal operation of the boiler water level is 0 ± 40mmH2O, the maximum does not exceed 0 ± 80mmH2O, the normal water pressure of 5.5MPa, to allow the fluctuation range of 4.5-6.0MPa, normal pressure boiler feed water temperature should be 105 degrees Celsius. 3, steam flow is not larger than the normal water boiler feedwater flow reasons, the measuring device instrument to do so. 4, the steam flow rate is less than the abnormal overheating damage reasons of water flow, water wall damage, damage to the economizer, the boiler is full of water, measuring device instrument to do so. 5, points on the furnace process CCP washed three times water gauge, pressures of 0.05-0.1MPa, 1.0MPa, 2.8MPa. 6, it is determined whether the normal water table and put into operation to see if the water level fluctuates slightly exemplar. 7, the boiler water pressure test and the test is divided into P overpressure test of two, when the water pressure P test, the boosting speed of not more than 0.35MPa 0.5MPa down rate does not exceed per minute. To the boiler water blowdown 8, the pressure in the boiler shutdown boiler water temperature drops below 80 degrees Celsius. 9, the position of each ordinary pressure test is hydrophobic doors: a door opening, the second door is closed. 10, the boiler-burner with a swirling-type and DC type two. 11, elemental analysis of coal with a composition: C, H, O, N, S, moisture, ash. 12, the main component of the blast furnace gas is: CO.'S time, nitrogen gas, blast furnace gas pressure is lower than 1500Pa, the user must reduce the amount of gas. Fire stop its pressure 1000Pa, working pressure 4000-8000Pa, the upper limit for the dangerous pressure 10000Pa, the lower limit is 2000Pa. 13, the main component of the coke oven gas: CO, nitrogen gas, coke oven gas pressure is lower than 1500Pa, must reduce the amount of gas, which pressure is 500Pa fire stop, working pressure 5000-7000Pa, the upper limit is 8000 Pa pressure the risk, the lower limit is 1500Pa . 14, the high, the main features of coke oven gas is flammable, explosive, toxic. 15, proximate analysis of coal with a volatile content, fixed carbon, ash and moisture. 16, boiler water circulation loop fault has stagnated, cycling back down the tube vaporization, soft drinks stratification. 17, the pulverized coal burning furnace radiation heat from a heat source of flame, high temperature flue gas convection heat. 18, the pulverized coal ignition and quick combustion conditions are sufficiently high temperature furnace, a sufficient amount of air mixed well, pulverized coal and air. Enough burn time. 19, ignition of pulverized coal into the combustion stage, the combustion stage, burning ember stage. 20, boiler mechanical rolling bearing does not exceed a predetermined temperature 80 degrees Celsius, the slide bearing does not exceed 40 degrees Celsius. 21, with factors affecting the steam load boiler water, boiler water salinity, pressure change, the vapor space of the drum height. 22, the principle of the steam separator drum gravity separation, inertial separation, centrifugal separation, separation of the water film. 23, the first ignition of the pulverized coal volatiles, fixed carbon is the latest ignition, the combustion of carbon is the longest. 24, steam soluble salt contaminated steam quality reasons, mechanical carryover. 25, the normal operation of the boiler drum water level in the glass tube than the water level high 50MM, when the water level in the steam table overall door leak, the water level high water table, the total gate leakage when the water level is low. 26, a method for enhancing heat transfer with a heat transfer coefficient is increased, raising the average temperature difference between the heat transfer, the heat transfer area is increased. 27, into the boiler furnace wall refractory layer, three-layer insulating layer and the sealing layer. 28, light blue flame blast furnace gas, as a bright golden yellow flame co-firing light yellow flame, coal, coke oven gas when the combustion gas as a combustion time. 29, the boiler by the "pot" and "furnace" composition, "pan" refers to a soft drink system is mainly composed of the drum, the downcomer, the header, waterwall, economizer, superheater composition; "oven" refers to a combustion system, a furnace, a burner, an air preheater composition. Calorific value 3.27GJ 30,1 tons of steam.

Boiler structure have? The whole structure, including boiler and boiler auxiliary equipment of two parts. Boiler furnace, drum, burner, water wall superheater, economizer, air preheater, and the furnace wall, etc. The main frame member constituting the core part of the steam production, called boiler. Boiler body is in two main parts and drum furnace. Also known as the furnace combustion chamber, fuel combustion for space. The solid fuel on to the grate, referred to as a fire bed combustion furnace Stoker, also known as fire bed furnace; solid fuel furnace liquid, gas or pulverized, is injected into the combustion chamber is called the fire chamber burner, also known as the furnace fire chamber; air coal particles burn hold it was boiling, and the furnace is inferior fuel suitable for combustion is called fluidized bed furnace, also called fluidized bed furnace; coal particles so that an air flow rotated at high speed, and strongly called fire cylindrical cyclone furnace hearth. The furnace cross-section is generally square or rectangular. Combustion fuel to form a flame in the furnace and high temperature flue gas, so the hearth around the furnace wall is made of refractory material and insulation material. On the inner surface of the wall of the furnace waterwall tubes often laid, it will not burn both protect the furnace wall, and absorb a large amount of radiation heat of the flame and the high temperature flue gas. Furnace design needs to fully consider the characteristics of the fuel used. Each boiler should be fueled with the original design of the fuel. Boilers running economy and reliability are likely to vary greatly reduced when using the characteristics of fuel combustion. And the natural circulation drum is repeatedly forced circulation boiler receiving feedwater to the economizer, the coupling cycle and supplying saturated steam superheater cylindrical vessel. Simplified drum made from high quality steel plate, is one of the heaviest components of the boiler.

coal heating steam boiler 3 ton per hour Related Information

coal consumption per hour of a boiler Sitong Wood

Coal Or Wood Fired 3 Ton Per Hour Steam Boiler,Boiler For Steam Distillation,Steam Boiler Types, Find Complete Details about Coal Or Wood Fired 3 Ton Per Hour Steam Product list ¥ 0.00 DZL Coal Fired Steam Boiler The boiler body is a single cylinder type, there are left and right double rows of fire pipe bundles inside the boiler cylinder to

Get A Quote

industrial gas fired 3 ton 3ton steam boiler

+3 +ton +boiler Industrial gas fired Boiler +3 +ton +boiler in Sugar Mill. Steam is very important for the sugar mill. Steam boiler is used for heating, gelatinization, and saccharify, etc. Heating equipment is equipped under mash kettle, and then steam produced by +3 +ton +boiler enter into the heating equipment, and

Get A Quote

steam boiler kg hr kcal h Gas Boilers Supplier

Hi there Can someone help, I have a steam boiler, and have the KG Per hour steam rating the boiler can acheive (15,000kg/hr), and need to convert that to the water kcal/h how much ton of steam boiler IBR boiler. kcal h how much ton of steam boiler china boiler

Get A Quote

2 ton steam boiler

2018-6-28 · Steam boiler is a horizontal three-pass shell type dual wet back boiler. The 2 ton steam boiler has an automatic control systems, energy saver and other auxiliary equipment and valves instrumentation. 2ton per hour steam boilers from manufacturer ZG : Natural Efficiency Up to 85% efficiency Radiant heat is maximized across the primary heating

Get A Quote

20 ton h steam boiler - Steam Boiler

Steam boiler is used for heating, gelatinization, and saccharify, etc. Heating equipment is equipped under mash kettle, and then steam produced by 5 ton boiler 0.1th LPGsteam boiler Manufacturer of industrial steam May 15, 2019 · 3 t h lpg fired steam boiler supply hot water boiler Sep 17, 2018 · 5 tonh lpg gas boilers. Learn More

Get A Quote

2. BOILERS

2017-9-8 · of heating surface of a boiler is expressed in square meters. The larger the heating surface a boiler has, the more efficient it becomes. The quantity of the steam produced is indicated in tons of water evap-orated to steam per hour. Maximum continuous rating is the hourly evaporation that can be maintained for 24 hours.

Get A Quote

20 ton h steam boiler - Steam Boiler

Steam boiler is used for heating, gelatinization, and saccharify, etc. Heating equipment is equipped under mash kettle, and then steam produced by 5 ton boiler 0.1th LPGsteam boiler Manufacturer of industrial steam May 15, 2019 · 3 t h lpg fired steam boiler supply hot water boiler Sep 17, 2018 · 5 tonh lpg gas boilers. Learn More

Get A Quote

6 Ton Hour Coal Fired Steam Boiler - WHGLA

coal biomass fired boiler manufacturer. 1 bar steam boiler Industrial Coal Fired Boiler Gas Fired 10 bar 1.5 ton steam boiler me-boiler Gas Fired 10 bar 1.5 ton steam boiler. 1.Fire tube 3 pass oil gas steam boiler. 2.Combustion chamber with large volume; 3.Spirally corrugated tube, strengthening heat transfer and 1 Ton Per Hour Gas Steam

Get A Quote

10 Ton Gas Fired Steam Boiler Consumption Per Hour

2019-11-28 · The rated evaporation capacity of the boiler is 10 tons per hour, the calorific value of natural gas is 35.438 MJ/Nm3, and the boiler efficiency is calculated at 95%. The gas consumption per hour of the 10 ton boiler: 7 MW*3600s/35.53 MJ/Nm3/95%=746 m3/h. Of course, the above formula is

Get A Quote

Babcock Steam Boiler 1 Ton Hour - meerkotten

5000 Kg Per Hour Steam Boiler - Babcock Steam Boiler 1 Ton Hour - luxushaeppchen.de. 3ton steam capacity per hour boiler Industrial Boiler. 2018-3-5 · Rated steam temperature: 184/194/204/214/224 1 ton per hour steam boiler is a small steam boiler, and widely used in construction equipment industry, apparel clothing, washing, ironing, food industry, sauna What is the gas consumption of the 2

Get A Quote

15 tph gas steam boiler tons per hour tons per hour

15 Ton Per Hour Diesel Oil Fired Boiler Pri. 5 tons per hour oil boiler Steam Boiler Producer. 5 Ton Steam Boiler, 5 Ton Steam Boiler Suppliers Best price WNS 5 ton per hour capacity industrial fire tube natural gas heavy diesel light oil fired steam boiler with burner5 ton per hour gas and oil steam boiler for maize in 5 ton per hour gas and oil steam boiler for maize in polutry feed

Get A Quote

China Gas Boiler, Steam Boiler, Coal Boiler Supplier

China Gas Boiler Supplier, Steam Boiler, Coal Boiler Manufacturers/ Suppliers - Henan Yuanda Boiler Corporation Ltd. Henan Yuanda Boiler Corporation Ltd. Diamond Member. Audited Supplier. Zhoukou, Henan, China 1 Ton 2 Ton 4 Ton 6 Ton 8 Ton Per Hour Capacity 12 Bar Pressure Coal Fired Steam Boiler. Min. Order: 1 set

Get A Quote

Small O.5 Ton Per Hour Gas,Oil,Coal Fuel Steam Boiler

Small O.5 Ton Per Hour Gas,Oil,Coal Fuel Steam Boiler With Reasonable Price, Find Complete Details about Small O.5 Ton Per Hour Gas,Oil,Coal Fuel Steam Boiler With Reasonable Price,Heavy Fuel Oil Boilers,Coal Fired Steam Boiler,Oil Field Steam Boiler from Boilers Supplier or Manufacturer-Henan Dafu Mechanical Import And Export Co., Ltd.

Get A Quote

3 ton boiler fuel consumption

3 ton per hour boiler gas consumption Horizonta. 3 ton per hour boiler gas consumption. April 5, 2019 by horizontalsteamboiler Leave a Comment. Quick inquiry: I need the quotation of, the fuel is, the pressure is, this capacity is, My Name is, my Email is, my phone number is, Please Send the detail information for me! (PDF) Steam Boiler

Get A Quote

10 ton industrial coal fired steam boiler

Two sets of the 10 ton per hour oil fired steam boiler use for textile mill plant in Bangladesh. thermal efficiency is 92%. SZL Water Tube Coal Steam Boiler This series boiler is horizontal type water tube 3 pass coal fired steam boiler.

Get A Quote